1.
J Child Neurol ; 26(12): 1522-4, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21642615

RESUMO

We determined the serum concentration of biotin, zinc, antiepileptic drugs, and biotinidase enzyme activity in 20 children treated with valproic acid, in 10 children treated with carbamazepine, and in 75 age- and sex-matched healthy controls. There were no significant differences in the serum levels of biotin, and biotinidase enzyme activity between the patients treated with valproic acid, the patients treated with carbamazepine, and the control group. Zinc serum levels were lower in the patients treated with valproic acid and with carbamazepine than in the control group, but within the normal range. Hair loss was observed in 3 patients treated with valproic acid, with normal serum levels of biotin, zinc, and biotinidase activity, and the alopecia disappeared with the oral administration of biotin (10 mg/d) in 3 months. These results suggest that the treatment with valproic acid does not alter the serum levels of biotin, zinc, and biotinidase enzyme activity.


Assuntos
Anticonvulsivantes/uso terapêutico , Biotina/sangue , Biotinidase/sangue , Carbamazepina/uso terapêutico , Convulsões/sangue , Convulsões/tratamento farmacológico , Ácido Valproico/uso terapêutico , Zinco/sangue , Adolescente , Criança , Feminino , Humanos , Masculino
2.
Magnes Res ; 21(1): 51-7, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18557134

RESUMO

Serum Mg is an important biochemical parameter in the context of clinical medicine for monitoring patients and for helping to diagnose some pathologies. The clinical laboratories must offer analytical results of quality in all parameters determined, demonstrating this way the laboratory "skill competence". The aim of this study was to revalidate (ISO 15189 standard) some different colorimetric methods for Mg determination in serum used in clinical and/or biochemical laboratories in four hospitals in Spain, on the basis of results of interlaboratory comparison programmes: Bio-Rad EQAS and external quality control SEQC. Precision and inaccuracy were estimated by analysis of records of an external quality control programme for Mg. The precision and inaccuracy values obtained were both less than 10%, except in one hospital in which the precision was less than 15%. These values of precision and inaccuracy obtained may be considered highly satisfactory taking into account the validation requirement for these ones: less than 10%. These findings demonstrate the effectiveness of the new revalidation methodology for diagnostic methods in medicine, which does not require any disruption of the laboratory's routine activity and which can be used even if the method in question has not been validated previously. It is also suggested that the ideas and requirements of ISO 15189 should be followed by the research laboratories.


Assuntos
Técnicas de Laboratório Clínico/normas , Laboratórios Hospitalares/normas , Magnésio/sangue , Humanos , Reprodutibilidade dos Testes , Espanha